AUGOS
    Article

    Protecting Your Power Factor Correction (PFC) System: The Critical Threat of Harmonics

    Harmonics, caused by non-linear loads, are silent threats that sabotage Power Factor Correction efficiency, causing equipment overheating and high costs. Learn the 5 ways harmonics affect PFC and how Augos can mitigate the risk.

    5 Ways
    Harmonics Sabotage PFC
    THD
    Total Harmonic Distortion
    Mitigation
    Essential Protection

    The Challenge: Harmonics Threaten PFC Investment

    Power Factor Correction (PFC) is fundamental to reducing electricity demand charges and increasing system efficiency. However, in modern commercial and industrial environments, a hidden threat—harmonics—can completely undermine these benefits.

    Harmonics are voltage or current waveforms that occur at frequencies that are integer multiples of the main frequency (50 Hz in South Africa). They are created by non-linear loads like VFDs and LED lighting, causing overheating, lower power factor, wasted energy, and potentially catastrophic equipment malfunctions through resonance.

    The Augos Solution: 5 Ways Harmonics Sabotage PFC

    1. Creates Distortion Power Factor: Harmonics inject distortions, lowering the overall power factor. This new metric combines regular power factor with Total Harmonic Distortion (THD)—more harmonics equal lower PF and higher bills.

    2. Causes Overheating & Equipment Stress: Harmonics lead to excessive current flow, dramatically increasing operating temperatures of transformers, motors, and cables, accelerating wear and increasing premature failure risk.

    3. Increases System Losses: Increased current and resistance from harmonics results in greater energy dissipation—wasted power that negates PFC efficiency gains.

    4. Triggers Dangerous Resonance: PFC capacitors can resonate with harmonic frequencies, amplifying harmonic levels and causing severe voltage distortion leading to catastrophic malfunctions.

    5. Reduces System Capacity: Harmonics increase overall current, taking up valuable capacity and potentially requiring larger, more expensive equipment upgrades.

    The Result: Holistic PFC & Harmonic Mitigation

    A holistic approach that considers both power factor correction and harmonic mitigation is key to a well-balanced and reliable electrical system. For guaranteed ROI, combine PFC with advanced Harmonic Mitigation.

    Mitigation strategies include Active and Passive Harmonic Filters (using electronics or tuned circuits to cancel/block frequencies), proper Capacitor Design (sized and de-rated to prevent resonance), and continuous Harmonic & Load Reporting to catch issues early. The rapid VSD and LED adoption in South Africa means harmonic mitigation is essential for long-term PFC ROI protection.

    Key Takeaways

    Harmonics from non-linear loads sabotage PFC efficiency and cause equipment damage

    5 critical impacts: distortion power factor, overheating, increased losses, resonance, and reduced capacity

    Holistic approach required: combine PFC with harmonic filters, proper capacitor design, and continuous monitoring

    South African VSD and LED adoption makes harmonic mitigation essential for PFC ROI protection

    Article Tags

    Energy Intelligence PlatformEnergy EfficiencyPower Factor & DemandHarmonic & Load StudyGeneral/AllArticle

    Ensure Your PFC Investment Delivers Long-Term Savings

    Contact Augos for a Harmonic and Power Factor Correction Survey to accurately measure your THD levels and design a resilient solution.